Laminator Assembly
Standard Towers with Slitters
This installation is simple; the towers are installed onto the machine side panels
using the included hardware. Distinguish the towers from left and right, the right
tower has the extra threaded hole with a ball plunger inserted. The inside face of
this right tower is distinguished by the chamfered mounting hole.
1. Install left tower using two 5/16 x ½” long, hex head bolts.
2. Install right tower (ball plunger) with the countersunk hole located toward
the front of the laminator and toward the center. Use one 5/16 x ½” long,
hex head bolt in the rear hole
Use one 5/16 x ½” long flat head Allen screw in the front hole
Take note that on the right tower the rear bolt must be oriented so that the side
of the bolt is parallel to the side of the slitter-actuating handle (see diagram
below.). Do not over tighten bolt it is better that it be looser rather than over
tightened
Correct
Notice both bolt and arm lay flush and
parallel
Incorrect,
Notice tip on bolt is preventing arm
from seating